Honda Odyssey Service Manual: A/C Refrigerant Recovery

Honda Odyssey Service Manual / HVAC / Cooling / A/C Refrigerant Recovery

caution
  • Air conditioning refrigerant or lubricant vapor can irritate your eyes, nose, or throat.

  • Be careful when connecting service equipment.

  • Do not breathe refrigerant or vapor.

NOTE:

  • If accidental system discharge occurs, ventilate the work area before resuming service.

  • Additional health and safety information may be obtained from the refrigerant and lubricant manufacturers.

  1. Connect an R-134a refrigerant recovery/recycling/charging station (A) to the high-pressure service port (B) and the low-pressure service port (C), as shown, following the equipment manufacturer's instructions.

  2. ACB
  3. Measure the amount of refrigerant oil removed from the A/C system after the recovery process is completed. Be sure to put the same amount of new refrigerant oil back into the A/C system before charging.

    Cooling

    A/C Service Tips and Precautions

    See More:

    Honda Odyssey Service Manual > Heated Cooled System: Seat Heater Control Unit Input Test/Replacement
    NOTE: SRS components are located in this area. Review the SRS component locations, and precautions and procedures   before doing repairs or servicing. Before testing, make sure the No. A3-4 (AS FB-1) (50 A) fuse in the main under-hood fuse box, and the No. C22 (15 A) fuse in the driver's u ...