Disconnect the 7P connector (A) from the front air mix control
motor (B). Remove the self-tapping screws and the front air mix control
motor from the heater unit.
Make sure the air mix door and linkage move
smoothly. Then install the motor in the reverse order of removal. Make
sure the pin on the motor is properly engaged with the linkage. After
installation, make sure the motor runs smoothly.