1 |
PNK |
M-HOT-Rr |
Output to drive rear air mix control motor to HOT side |
With ignition switch ON (II) and rear air mix control motor moving to HOT: battery voltage |
2 |
BLU |
M-HEAT-Rr |
Outputs to drive rear mode control motor to HEAT side |
With ignition switch ON (II) and rear mode control motor moving to HEAT: battery voltage |
3 |
YEL |
M-VENT-Rr |
Outputs to drive rear mode control motor to VENT side |
With ignition switch ON (II) and rear mode control motor moving to VENT: battery voltage |
4 |
Not used |
Not used |
??? |
??? |
5* |
LT BLU |
Teva-Rr |
Detects rear evaporator temperature sensor signal |
With ignition switch ON (II): about 1.0-4.0 V (depending on rear evaporator temperature) |
6 |
ORN |
AMD-P-Rr |
Detects potentiometer signal of rear air mix control motor (door position) |
With ignition switch ON (II): about 1.0-4.0 V (depending on rear air mix control motor position) |
7 |
GRN |
M-COOL-Rr |
Output to drive rear air mix control motor to COOL side |
With ignition switch ON (II) and rear air mix control motor moving to COOL: battery voltage |
8 |
Not used |
Not used |
??? |
??? |
9 |
PUR |
S5V |
Outputs sensor 5 V |
With ignition switch ON (II): about 5.0 V |
10 |
Not used |
Not used |
??? |
??? |
11 |
BLK |
SENS-COM |
Sensor ground |
Less than 0.2 V at all times |
12 |
RED |
MDD-P-Rr |
Detects potentiometer signal of rear mode control motor (door position) |
With ignition switch ON (II): about 1.5-4.0 V (depending on rear mode control motor position) |